Home  |  Disclaimer   |
 
 

Press 3 DSF Corus IJmuiden 

Design Specifications

Client :
Dolomietsteenfabriek Tata IJmuiden
Object:Stone Press 3
Design pressure: 230 barg
Diameter: Ø 880 mm

Problem definition

The tread of the valve (M470) turned out to be leaking after 30 years of produciton. During the repair a crack was discoverd. In short notice a repartion principle had to be proposed. So the standstill period could be as short as possible.


Contribution of Stemar Engineering

In the first stage Stemar Engineering made a stress calculation with fatique incorporated. 

After the crack was found we advised the Tata-project team with the possibilities for a durable repair. Because of the high amount of cycles and high pressure with large diameter, fatique and forces played an important role.

Result

After the successful repair press 3 is back in production.